x
This website uses cookies to improve your experience. By continuing to use this website, you consent to their use. Learn more

CoreSite

12369 Sunrise Valley Drive

Reston, VA

VA3

COLOCATION

About VA3 Data Center

OVERVIEW


CoreSite operates this data center at 12369 Sunrise Valley Drive in Reston. The 940,000 SF retrofit facility provides colocation services to a variety of customers. Connectivity to PacketFabric and Google Cloud is available for customer use. The UPS systems are N/N+1/2N redundant and the generators are N+2 redundant.

4Q22 Northern Virginia Data Center Market Report

POWER


??? NN

Commissioned Power

??? NN

Available Power

Login to view capacity data

??? NN

Under Construction Power

??? NN

Planned Power

  • Estimated Power Cost
    --
  • Single or Dual Feed
    Dual Feed
  • On-Site Substation
    Yes
  • Power Provider
    Dominion Virginia Power
  • Number of Substations
    --
  • Estimated kW/Cabinet
    --
  • Additional Information
    --

BUILDING


??? ??

Commissioned Space

??? ??

Available Space

Login to view capacity data

??? ??

Under Construction Space

??? ??

Planned Space

  • Status
    Operational
  • Building Size
    940000 SF
  • Year Built
    1985
  • Building Floors
    4
  • Building Owner
    CoreSite
  • Purpose Built or Retrofit
    Retrofit
  • On-Site Office Space
    Yes
  • On-Site Conf Room
    Yes
  • On-Site Break Room
    Yes

GET A QUOTE

No Obligation. Free. Privacy Guaranteed.

Cabinet Requirements

Additional Options

Redundant power feed

Three-phase power


Committed Bandwidth*

Committed or "flat-rate" bandwidth is an unmetered connection where you can use any amount up to the limit for the same price every month.

Please enter the committed bandwidth amount

Burstable Bandwidth

Burstable or "fractional commit" is where you pay for a certain amount of bandwidth, but can utilize additional bandwidth as needed during times of peak demand. Additional charges will apply for utilizing bandwidth above the base level. E.g. "100 Mbps w/40Mbps Committed" or "20 Mbps burstable to 1000 Mbps"

{{ errors.first('burstableBandwidth') }}

Contact Information

CONNECTIVITY


Provider (48) PoPs Services

INFRASTRUCTURE


  • UPS Redundancy
    N/N+1/2N
  • Generator Redundancy
    N+2
  • Generator Description
    24-hour minimum on-site fuel storage
  • Cooling Redundancy
    N+2
  • Cooling Description
    Campus cooling towers and chiller plants; state-of-the-art chillers with evaporative condensing units for air- and water-side economization

COMPLIANCE


  • --

    SSAE-16
  • --

    SSAE-18
  • --

    HIPAA
  • --

    PCI
  • --

    DIACAP
  • --

    Energy Star
  • --

    ISO
  • --

    FISMA
  • --

    FEDRAMP
  • --

    NIST
  • --

    SOC 1
  • --

    SOC 2
  • --

    SOC 3
  • --

    Uptime Institute MO Site Award
  • --

    Uptime Institute Tier III Constructed
  • --

    Uptime Institute Tier III Design

SERVICES


  • --

    Private Suites
  • --

    Dedicated Infrastructure
  • --

    Cloud
  • SLA 99.9%

SECURITY


  • --

    Perimeter Fencing
  • --

    Card Key Access
  • --

    CCTV
  • --

    Man Trap
Clear All

BACK TO PROFILE

REQUEST A QUOTE FROM CoreSite VA3 FACILITY

Tell us a little about your needs before we connect you with a CoreSite representative.

DATA CENTER REQUIREMENTS


BASIC INFORMATION


By clicking send, I agree that datacenterHawk will send this information to CoreSite.

SEND QUOTE

GET A QUOTE