Cyxtera Technologies

400 Tijeras Avenue NW

Albuquerque, NM

ABQ1-A,B

COLOCATION

About ABQ1-A,B Data Center

OVERVIEW


Cyxtera Technologies operates this facility located at 400 Tijeras Avenue NW in Albuquerque. The building offers a total of 421,290 SF. On the interconnectivity side, the facility offers connections to on-net fiber providers including Time Warner Cable, Verizon Communications and Comcast. Infrastructure in the data center includes N+1 UPS and 2N generator redundancies, with a cooling configuration of N+1.

POWER


??? NN

Commissioned Power

??? NN

Available Power

Login to view capacity data

??? NN

Under Construction Power

??? NN

Planned Power

  • Estimated Power Cost
    --
  • Single or Dual Feed
    Dual Feed
  • On-Site Substation
    No
  • Power Provider
    Public Service Company of New Mexico
  • Number of Substations
    More
  • Estimated kW/Cabinet
    --
  • Additional Information
    --

BUILDING


??? ??

Commissioned Space

??? ??

Available Space

Login to view capacity data

??? ??

Under Construction Space

??? ??

Planned Space

  • Status
    Operational
  • Building Size
    421290 SF
  • Year Built
    1981
  • Building Floors
    7
  • Building Owner
    Omninet Capital
  • Purpose Built or Retrofit
    Purpose Built
  • On-Site Office Space
    Yes
  • On-Site Conf Room
    Yes
  • On-Site Break Room
    Yes

GET A QUOTE

No Obligation. Free. Privacy Guaranteed.

Cabinet Requirements

Additional Options

Redundant power feed

Three-phase power


Committed Bandwidth*

Committed or "flat-rate" bandwidth is an unmetered connection where you can use any amount up to the limit for the same price every month.

Please enter the committed bandwidth amount

Burstable Bandwidth

Burstable or "fractional commit" is where you pay for a certain amount of bandwidth, but can utilize additional bandwidth as needed during times of peak demand. Additional charges will apply for utilizing bandwidth above the base level. E.g. "100 Mbps w/40Mbps Committed" or "20 Mbps burstable to 1000 Mbps"

{{ errors.first('burstableBandwidth') }}

Contact Information

CONNECTIVITY


Provider (11) PoPs Services

INFRASTRUCTURE


  • UPS Redundancy
    N+1
  • UPS Description
    Eaton UPS systems; distributed redundant configuration
  • Generator Redundancy
    2N
  • Generator Description
    6 MW generator capacity; six (6) 1 MW generators are shared with other tenants in building; 55 hours diesel fuel runtime at current load and 27 hours at full load
  • Cooling Redundancy
    N+1
  • Cooling Description
    1,500 tons cooling capacity; hot/cold aisle cooling configuration; cooling temperature ranges from 59-90 degrees Fahrenheit

COMPLIANCE


  • --

    SSAE-16
  • --

    SSAE-18
  • --

    HIPAA
  • --

    PCI
  • --

    DIACAP
  • --

    Energy Star
  • --

    ISO
  • --

    FISMA
  • --

    FEDRAMP
  • --

    NIST
  • --

    SOC 1
  • --

    SOC 2
  • --

    SOC 3
  • --

    Uptime Institute MO Site Award
  • --

    Uptime Institute Tier III Constructed
  • --

    Uptime Institute Tier III Design

SERVICES


  • --

    Private Suites
  • --

    Dedicated Infrastructure
  • --

    Cloud
  • SLA 99.9%

SECURITY


  • --

    Perimeter Fencing
  • --

    Card Key Access
  • --

    CCTV
  • --

    Man Trap
Clear All

BACK TO PROFILE

REQUEST A QUOTE FROM Cyxtera Technologies ABQ1-A,B FACILITY

Tell us a little about your needs before we connect you with a Cyxtera Technologies representative.

DATA CENTER REQUIREMENTS


BASIC INFORMATION


By clicking send, I agree that datacenterHawk will send this information to Cyxtera Technologies.

SEND QUOTE

GET A QUOTE