x
This website uses cookies to improve your experience. By continuing to use this website, you consent to their use. Learn more

Cyxtera Technologies

45901 Nokes Boulevard

Sterling, VA

IAD1-A

COLOCATION

About IAD1-A Data Center

OVERVIEW


Cyxtera Technologies operates this data center located at 45901 Nokes Boulevard in the Northern Virginia market. The data center is a 88,489 SF purpose built facility. AT&T, AboveNet and CenturyLink are some of the fiber options available at IAD1-A. To ensure continuity of service, the facility maintains N+1 generator redundancy.

4Q22 Northern Virginia Data Center Market Report

POWER


??? NN

Commissioned Power

??? NN

Available Power

Login to view capacity data

??? NN

Under Construction Power

??? NN

Planned Power

  • Estimated Power Cost
    $0.070 - 0.070
  • Single or Dual Feed
    Dual Feed
  • On-Site Substation
    No
  • Power Provider
    Dominion Virginia Power
  • Number of Substations
    More
  • Estimated kW/Cabinet
    --
  • Additional Information
    --

BUILDING


??? ??

Commissioned Space

??? ??

Available Space

Login to view capacity data

??? ??

Under Construction Space

??? ??

Planned Space

  • Status
    Operational
  • Building Size
    88489 SF
  • Year Built
    1998
  • Building Floors
    1
  • Building Owner
    Mapletree Investments
  • Purpose Built or Retrofit
    Purpose Built
  • On-Site Office Space
    No
  • On-Site Conf Room
    Yes
  • On-Site Break Room
    Yes

GET A QUOTE

No Obligation. Free. Privacy Guaranteed.

Cabinet Requirements

Additional Options

Redundant power feed

Three-phase power


Committed Bandwidth*

Committed or "flat-rate" bandwidth is an unmetered connection where you can use any amount up to the limit for the same price every month.

Please enter the committed bandwidth amount

Burstable Bandwidth

Burstable or "fractional commit" is where you pay for a certain amount of bandwidth, but can utilize additional bandwidth as needed during times of peak demand. Additional charges will apply for utilizing bandwidth above the base level. E.g. "100 Mbps w/40Mbps Committed" or "20 Mbps burstable to 1000 Mbps"

{{ errors.first('burstableBandwidth') }}

Contact Information

CONNECTIVITY


Provider (16) PoPs Services

INFRASTRUCTURE


  • UPS Redundancy
    N+2
  • UPS Description
    UPS type: Batteries
  • Generator Redundancy
    N+1
  • Generator Description
    Six (6) generators; five (5) 1,250 kW generators and one (1) 1,500 kW generator; more than 24 hours diesel fuel runtime at full load
  • Cooling Redundancy
    N+1
  • Cooling Description
    Temperature ranges between 59-90 degrees Fahrenheit; hot/cold aisle configuration

COMPLIANCE


  • --

    SSAE-16
  • --

    SSAE-18
  • --

    HIPAA
  • --

    PCI
  • --

    DIACAP
  • --

    Energy Star
  • --

    ISO
  • --

    FISMA
  • --

    FEDRAMP
  • --

    NIST
  • --

    SOC 1
  • --

    SOC 2
  • --

    SOC 3
  • --

    Uptime Institute MO Site Award
  • --

    Uptime Institute Tier III Constructed
  • --

    Uptime Institute Tier III Design

SERVICES


  • --

    Private Suites
  • --

    Dedicated Infrastructure
  • --

    Cloud
  • SLA 99.9%

SECURITY


  • --

    Perimeter Fencing
  • --

    Card Key Access
  • --

    CCTV
  • --

    Man Trap
Clear All

BACK TO PROFILE

REQUEST A QUOTE FROM Cyxtera Technologies IAD1-A FACILITY

Tell us a little about your needs before we connect you with a Cyxtera Technologies representative.

DATA CENTER REQUIREMENTS


BASIC INFORMATION


By clicking send, I agree that datacenterHawk will send this information to Cyxtera Technologies.

SEND QUOTE

GET A QUOTE