DataVerge

111 Town Square Place

Jersey City, NJ

CGNJ1

COLOCATION

About CGNJ1 Data Center

OVERVIEW


DataVerge's CGNJ1 facility is located at 111 Town Square Place in the Northern New Jersey market. The 480,000 SF retrofit facility provides colocation services to a variety of customers. Customers have a range of connectivity options at the facility to fiber providers like Comcast, Level 3 (Lumen Technologies) and Verizon Communications. The facility also offers N+1 generator redundancy and N+1 cooling redundancy.

1Q23 Northern New Jersey Data Center Market Report

POWER


??? NN

Commissioned Power

??? NN

Available Power

Login to view capacity data

??? NN

Under Construction Power

??? NN

Planned Power

  • Estimated Power Cost
    --
  • Single or Dual Feed
    --
  • On-Site Substation
    No
  • Power Provider
    --
  • Number of Substations
    --
  • Estimated kW/Cabinet
    --
  • Additional Information
    --

BUILDING


??? ??

Commissioned Space

??? ??

Available Space

Login to view capacity data

??? ??

Under Construction Space

??? ??

Planned Space

  • Status
    Operational
  • Building Size
    480000 SF
  • Year Built
    1988
  • Building Floors
    15
  • Building Owner
    LeFrak Commercial
  • Purpose Built or Retrofit
    Retrofit
  • On-Site Office Space
    Yes
  • On-Site Conf Room
    Yes
  • On-Site Break Room
    Yes

GET A QUOTE

No Obligation. Free. Privacy Guaranteed.

Cabinet Requirements

Additional Options

Redundant power feed

Three-phase power


Committed Bandwidth*

Committed or "flat-rate" bandwidth is an unmetered connection where you can use any amount up to the limit for the same price every month.

Please enter the committed bandwidth amount

Burstable Bandwidth

Burstable or "fractional commit" is where you pay for a certain amount of bandwidth, but can utilize additional bandwidth as needed during times of peak demand. Additional charges will apply for utilizing bandwidth above the base level. E.g. "100 Mbps w/40Mbps Committed" or "20 Mbps burstable to 1000 Mbps"

{{ errors.first('burstableBandwidth') }}

Contact Information

CONNECTIVITY


Provider (27) PoPs Services

INFRASTRUCTURE


  • UPS Redundancy
    N+1
  • UPS Description
    Backup power generation provided by 600kW diesel generator, 5,000 gallons of diesel fuel on-site
  • Generator Redundancy
    N+1
  • Generator Description
    Six (6) 2 MW emergency generators located on the roof; backup power generation provided by a 600 kW diesel generator with automatic transfer; 5,000 gallons of diesel fuel on-site
  • Cooling Redundancy
    N+1
  • Cooling Description
    Down-flow air distribution within raised floor environments; Glycol condenser water distribution: closed-loop system

COMPLIANCE


  • --

    SSAE-16
  • --

    SSAE-18
  • --

    HIPAA
  • --

    PCI
  • --

    DIACAP
  • --

    Energy Star
  • --

    ISO
  • --

    FISMA
  • --

    FEDRAMP
  • --

    NIST
  • --

    SOC 1
  • --

    SOC 2
  • --

    SOC 3
  • --

    Uptime Institute MO Site Award
  • --

    Uptime Institute Tier III Constructed
  • --

    Uptime Institute Tier III Design

SERVICES


  • --

    Private Suites
  • --

    Dedicated Infrastructure
  • --

    Cloud
  • SLA 99.9%

SECURITY


  • --

    Perimeter Fencing
  • --

    Card Key Access
  • --

    CCTV
  • --

    Man Trap
Clear All

BACK TO PROFILE

REQUEST A QUOTE FROM DataVerge CGNJ1 FACILITY

Tell us a little about your needs before we connect you with a DataVerge representative.

DATA CENTER REQUIREMENTS


BASIC INFORMATION


By clicking send, I agree that datacenterHawk will send this information to DataVerge.

SEND QUOTE

GET A QUOTE