H5 Data Centers

1625 Rockwell Avenue

Cleveland, OH

CTC

COLOCATION

About CTC Data Center

OVERVIEW


H5 Data Centers operates this facility located at 1625 Rockwell Avenue in Cleveland. The data center is a 351,000 SF retrofit facility. Customers have a range of connectivity options at the facility to fiber providers like Cogent Communications, Verizon Communications and Arelion. Infrastructure redundancies include 2N for cooling and 2N for UPS.

POWER


??? NN

Commissioned Power

??? NN

Available Power

Login to view capacity data

??? NN

Under Construction Power

??? NN

Planned Power

  • Estimated Power Cost
    $0.058 - 0.059
  • Single or Dual Feed
    Dual Feed
  • On-Site Substation
    No
  • Power Provider
    The Illuminating Company
  • Number of Substations
    Two
  • Estimated kW/Cabinet
    20.00
  • Additional Information
    --

BUILDING


??? ??

Commissioned Space

??? ??

Available Space

Login to view capacity data

??? ??

Under Construction Space

??? ??

Planned Space

  • Status
    Operational
  • Building Size
    351000 SF
  • Year Built
    1920
  • Building Floors
    4
  • Building Owner
    H5 Data Centers
  • Purpose Built or Retrofit
    Retrofit
  • On-Site Office Space
    Yes
  • On-Site Conf Room
    Yes
  • On-Site Break Room
    Yes

GET A QUOTE

No Obligation. Free. Privacy Guaranteed.

Cabinet Requirements

Additional Options

Redundant power feed

Three-phase power


Committed Bandwidth*

Committed or "flat-rate" bandwidth is an unmetered connection where you can use any amount up to the limit for the same price every month.

Please enter the committed bandwidth amount

Burstable Bandwidth

Burstable or "fractional commit" is where you pay for a certain amount of bandwidth, but can utilize additional bandwidth as needed during times of peak demand. Additional charges will apply for utilizing bandwidth above the base level. E.g. "100 Mbps w/40Mbps Committed" or "20 Mbps burstable to 1000 Mbps"

{{ errors.first('burstableBandwidth') }}

Contact Information

CONNECTIVITY


Provider (19) PoPs Services

INFRASTRUCTURE


  • UPS Redundancy
    2N
  • UPS Description
    Four (4) 1.2 MW Schneider Electric Symmetra MW Scalable UPS Systems (each expansion phase)
  • Generator Redundancy
    2N
  • Generator Description
    Five (5) 2.4 MW diesel generators; emergency generator farm designed for 48-hour runtime
  • Cooling Redundancy
    2N
  • Cooling Description
    Chilled water system with air side economizer

COMPLIANCE


  • --

    SSAE-16
  • --

    SSAE-18
  • --

    HIPAA
  • --

    PCI
  • --

    DIACAP
  • --

    Energy Star
  • --

    ISO
  • --

    FISMA
  • --

    FEDRAMP
  • --

    NIST
  • --

    SOC 1
  • --

    SOC 2
  • --

    SOC 3
  • --

    Uptime Institute MO Site Award
  • --

    Uptime Institute Tier III Constructed
  • --

    Uptime Institute Tier III Design

SERVICES


  • --

    Private Suites
  • --

    Dedicated Infrastructure
  • --

    Cloud
  • SLA 99.9%

SECURITY


  • --

    Perimeter Fencing
  • --

    Card Key Access
  • --

    CCTV
  • --

    Man Trap
Clear All

BACK TO PROFILE

REQUEST A QUOTE FROM H5 Data Centers CTC FACILITY

Tell us a little about your needs before we connect you with a H5 Data Centers representative.

DATA CENTER REQUIREMENTS


BASIC INFORMATION


By clicking send, I agree that datacenterHawk will send this information to H5 Data Centers.

SEND QUOTE

GET A QUOTE