NorthC Datacenters

Groningenhaven 26

COLOCATION

About NorthC Datacenters Data Center

OVERVIEW


This data center serves the Amsterdam market and is operated by NorthC Datacenters. The facility boasts a total of 86,111 SF and offers customers access to office space, conference rooms and break rooms. The facility also offers 2N generator redundancy and 2N cooling redundancy.

3Q22 Amsterdam Data Center Market Report

POWER


??? NN

Commissioned Power

??? NN

Available Power

Login to view capacity data

??? NN

Under Construction Power

??? NN

Planned Power

  • Estimated Power Cost
    --
  • Single or Dual Feed
    Dual Feed
  • On-Site Substation
    No
  • Power Provider
    Greenchoice
  • Number of Substations
    --
  • Estimated kW/Cabinet
    --
  • Additional Information
    --

BUILDING


??? ??

Commissioned Space

??? ??

Available Space

Login to view capacity data

??? ??

Under Construction Space

??? ??

Planned Space

  • Status
    Operational
  • Building Size
    86111 SF
  • Year Built
    --
  • Building Floors
    1
  • Building Owner
    NorthC
  • Purpose Built or Retrofit
    --
  • On-Site Office Space
    Yes
  • On-Site Conf Room
    Yes
  • On-Site Break Room
    Yes

GET A QUOTE

No Obligation. Free. Privacy Guaranteed.

Cabinet Requirements

Additional Options

Redundant power feed

Three-phase power


Committed Bandwidth*

Committed or "flat-rate" bandwidth is an unmetered connection where you can use any amount up to the limit for the same price every month.

Please enter the committed bandwidth amount

Burstable Bandwidth

Burstable or "fractional commit" is where you pay for a certain amount of bandwidth, but can utilize additional bandwidth as needed during times of peak demand. Additional charges will apply for utilizing bandwidth above the base level. E.g. "100 Mbps w/40Mbps Committed" or "20 Mbps burstable to 1000 Mbps"

{{ errors.first('burstableBandwidth') }}

Contact Information

CONNECTIVITY


Provider (1) PoPs Services

INFRASTRUCTURE


  • UPS Redundancy
    2N+1
  • UPS Description
    Dual UPS with batteries capable of 5 minutes at full load
  • Generator Redundancy
    2N
  • Generator Description
    Dual backup generators (type: SDMO Emergency Power System); sufficient diesel for 24 hours at full load; contingency agreements in place for non-stop diesel generator operation; three (3) 1 MW diesel generators
  • Cooling Redundancy
    2N
  • Cooling Description
    Up to 15 kW cooling capacity per rack; air handling units for the entire building; 100% cold corridor system in place for all racks; blind plates supplied in all racks for optimal airflow; chilled water cooling system with cold aisles

COMPLIANCE


  • --

    SSAE-16
  • --

    SSAE-18
  • --

    HIPAA
  • --

    PCI
  • --

    DIACAP
  • --

    Energy Star
  • --

    ISO
  • --

    FISMA
  • --

    FEDRAMP
  • --

    NIST
  • --

    SOC 1
  • --

    SOC 2
  • --

    SOC 3
  • --

    Uptime Institute MO Site Award
  • --

    Uptime Institute Tier III Constructed
  • --

    Uptime Institute Tier III Design

SERVICES


  • --

    Private Suites
  • --

    Dedicated Infrastructure
  • --

    Cloud
  • SLA 99.9%

SECURITY


  • --

    Perimeter Fencing
  • --

    Card Key Access
  • --

    CCTV
  • --

    Man Trap
Clear All

BACK TO PROFILE

REQUEST A QUOTE FROM NorthC Datacenters FACILITY

Tell us a little about your needs before we connect you with a NorthC Datacenters representative.

DATA CENTER REQUIREMENTS


BASIC INFORMATION


By clicking send, I agree that datacenterHawk will send this information to NorthC Datacenters.

SEND QUOTE

GET A QUOTE