DFW1 is a colocation data center in Grapevine operated by Rackspace. The 351,517 SF retrofit facility is designed to meet customer colocation needs. Those colocated at the facility have the ability to connect directly to cloud service platforms like Megaport, and can access fiber lines from companies like CenturyLink, AT&T and Zayo. DFW1's cooling infrastructure offers N+2 redundancy.

2Q22 Dallas/Fort Worth Data Center Market Report

POWER


??? NN

Commissioned Power

??? NN

Available Power

Login to view capacity data

??? NN

Under Construction Power

??? NN

Planned Power

  • Estimated Power Cost
    --
  • Single or Dual Feed
    Dual Feed
  • On-Site Substation
    No
  • Power Provider
    --
  • Number of Substations
    Two
  • Estimated kW/Cabinet
    --
  • Additional Information
    --

BUILDING


??? ??

Commissioned Space

??? ??

Available Space

Login to view capacity data

??? ??

Under Construction Space

??? ??

Planned Space

  • Status
    Operational
  • Building Size
    351517 SF
  • Year Built
    1998
  • Building Floors
    --
  • Building Owner
    Prologis
  • Purpose Built or Retrofit
    Retrofit
  • On-Site Office Space
    Yes
  • On-Site Conf Room
    No
  • On-Site Break Room
    No

GET A QUOTE

No Obligation. Free. Privacy Guaranteed.

Cabinet Requirements

Additional Options

Redundant power feed

Three-phase power


Committed Bandwidth*

Committed or "flat-rate" bandwidth is an unmetered connection where you can use any amount up to the limit for the same price every month.

Please enter the committed bandwidth amount

Burstable Bandwidth

Burstable or "fractional commit" is where you pay for a certain amount of bandwidth, but can utilize additional bandwidth as needed during times of peak demand. Additional charges will apply for utilizing bandwidth above the base level. E.g. "100 Mbps w/40Mbps Committed" or "20 Mbps burstable to 1000 Mbps"

{{ errors.first('burstableBandwidth') }}

Contact Information

CONNECTIVITY


Provider (4) PoPs Services

INFRASTRUCTURE


  • UPS Redundancy
    N+1
  • UPS Description
    Nine (9) 2,000 kVA Powerware UPS Systems
  • Generator Redundancy
    N+1
  • Generator Description
    Two sets of four (4) 1,500 kW Cummins diesel generators; two sets of four (4) 2,000 kW Cummins diesel generators; 48-hour on-site fuel capacity under full load
  • Cooling Redundancy
    N+2
  • Cooling Description
    7,500 tons cooling capacity; thirty-eight (38) air handling units & forty-nine (49) computer room air handling units all with HEPA filtration; five (5) 1,500-ton York YK centrifugal chillers w/ VSD; six (6) Marley cooling towers; five (5) chilled water loop pumps & condenser water loop pumps

COMPLIANCE


  • --

    SSAE-16
  • --

    SSAE-18
  • --

    HIPAA
  • --

    PCI
  • --

    DIACAP
  • --

    Energy Star
  • --

    ISO
  • --

    FISMA
  • --

    FEDRAMP
  • --

    NIST
  • --

    SOC 1
  • --

    SOC 2
  • --

    SOC 3
  • --

    Uptime Institute MO Site Award
  • --

    Uptime Institute Tier III Constructed
  • --

    Uptime Institute Tier III Design

SERVICES


  • --

    Private Suites
  • --

    Dedicated Infrastructure
  • --

    Cloud
  • SLA 99.9%

SECURITY


  • --

    Perimeter Fencing
  • --

    Card Key Access
  • --

    CCTV
  • --

    Man Trap
Clear All

BACK TO PROFILE

REQUEST A QUOTE FROM Rackspace DFW1 FACILITY

Tell us a little about your needs before we connect you with a Rackspace representative.

DATA CENTER REQUIREMENTS


BASIC INFORMATION


By clicking send, I agree that datacenterHawk will send this information to Rackspace.

SEND QUOTE

GET A QUOTE