Sungard Availability Services operates this facility in the London data center market. The data center is a 200,000 SF retrofit facility. On the interconnectivity side, the facility offers connections to on-net fiber providers including Epsilon Telecommunications, SSE Enterprise Telecoms and Colt Technology Services. The UPS systems are 2(N+1) redundant and the generators are N+1 redundant.

4Q22 London Data Center Market Report

POWER


??? NN

Commissioned Power

??? NN

Available Power

Login to view capacity data

??? NN

Under Construction Power

??? NN

Planned Power

  • Estimated Power Cost
    --
  • Single or Dual Feed
    Dual Feed
  • On-Site Substation
    No
  • Power Provider
    UK National Grid
  • Number of Substations
    Two
  • Estimated kW/Cabinet
    2.00 - 10.00
  • Additional Information
    --

BUILDING


??? ??

Commissioned Space

??? ??

Available Space

Login to view capacity data

??? ??

Under Construction Space

??? ??

Planned Space

  • Status
    Operational
  • Building Size
    200000 SF
  • Year Built
    1999
  • Building Floors
    2
  • Building Owner
    Digital Realty
  • Purpose Built or Retrofit
    Retrofit
  • On-Site Office Space
    Yes
  • On-Site Conf Room
    Yes
  • On-Site Break Room
    Yes

GET A QUOTE

No Obligation. Free. Privacy Guaranteed.

Cabinet Requirements

Additional Options

Redundant power feed

Three-phase power


Committed Bandwidth*

Committed or "flat-rate" bandwidth is an unmetered connection where you can use any amount up to the limit for the same price every month.

Please enter the committed bandwidth amount

Burstable Bandwidth

Burstable or "fractional commit" is where you pay for a certain amount of bandwidth, but can utilize additional bandwidth as needed during times of peak demand. Additional charges will apply for utilizing bandwidth above the base level. E.g. "100 Mbps w/40Mbps Committed" or "20 Mbps burstable to 1000 Mbps"

{{ errors.first('burstableBandwidth') }}

Contact Information

CONNECTIVITY


Provider (8) PoPs Services

INFRASTRUCTURE


  • UPS Redundancy
    2(N+1)
  • UPS Description
    500 kVA Eaton UPS modules in "A" and "B"; UPS battery autonomy supports 10 minutes at full load
  • Generator Redundancy
    N+1
  • Generator Description
    3 MVA sets; Generator fuel supply supports 72 hours at full load
  • Cooling Redundancy
    N+1
  • Cooling Description
    5 x 1500kW of cooling, provision for additional chillers; Temperature maintained at (22ºC +/- 2ºC); Chilled water cooling system

COMPLIANCE


  • --

    SSAE-16
  • --

    SSAE-18
  • --

    HIPAA
  • --

    PCI
  • --

    DIACAP
  • --

    Energy Star
  • --

    ISO
  • --

    FISMA
  • --

    FEDRAMP
  • --

    NIST
  • --

    SOC 1
  • --

    SOC 2
  • --

    SOC 3
  • --

    Uptime Institute MO Site Award
  • --

    Uptime Institute Tier III Constructed
  • --

    Uptime Institute Tier III Design

SERVICES


  • --

    Private Suites
  • --

    Dedicated Infrastructure
  • --

    Cloud
  • SLA 99.9%

SECURITY


  • --

    Perimeter Fencing
  • --

    Card Key Access
  • --

    CCTV
  • --

    Man Trap
Clear All

BACK TO PROFILE

REQUEST A QUOTE FROM Sungard Availability Services TC3 FACILITY

Tell us a little about your needs before we connect you with a Sungard Availability Services representative.

DATA CENTER REQUIREMENTS


BASIC INFORMATION


By clicking send, I agree that datacenterHawk will send this information to Sungard Availability Services.

SEND QUOTE

GET A QUOTE