beanfield Metroconnect

905 King Street W

Toronto, ON

COLOCATION

About beanfield Metroconnect Data Center

OVERVIEW


beanfield Metroconnect operates this facility in the Toronto data center market. The 112,000 SF building has delivered 300 kW to the market, with an additional 700 kW master-planned. Cooling systems are configured in N+1/2N redundancy.

2Q22 Toronto Data Center Market Report

POWER


??? NN

Commissioned Power

??? NN

Available Power

Login to view capacity data

??? NN

Under Construction Power

??? NN

Planned Power

  • Estimated Power Cost
    --
  • Single or Dual Feed
    Dual Feed
  • On-Site Substation
    No
  • Power Provider
    Toronto Hydro
  • Number of Substations
    One
  • Estimated kW/Cabinet
    4.00
  • Additional Information
    --

BUILDING


??? ??

Commissioned Space

??? ??

Available Space

Login to view capacity data

??? ??

Under Construction Space

??? ??

Planned Space

  • Status
    Operational
  • Building Size
    112000 SF
  • Year Built
    1985
  • Building Floors
    7
  • Building Owner
    Allied Properties REIT
  • Purpose Built or Retrofit
    Retrofit
  • On-Site Office Space
    No
  • On-Site Conf Room
    No
  • On-Site Break Room
    No

GET A QUOTE

No Obligation. Free. Privacy Guaranteed.

Cabinet Requirements

Additional Options

Redundant power feed

Three-phase power


Committed Bandwidth*

Committed or "flat-rate" bandwidth is an unmetered connection where you can use any amount up to the limit for the same price every month.

Please enter the committed bandwidth amount

Burstable Bandwidth

Burstable or "fractional commit" is where you pay for a certain amount of bandwidth, but can utilize additional bandwidth as needed during times of peak demand. Additional charges will apply for utilizing bandwidth above the base level. E.g. "100 Mbps w/40Mbps Committed" or "20 Mbps burstable to 1000 Mbps"

{{ errors.first('burstableBandwidth') }}

Contact Information

CONNECTIVITY


Provider (2) PoPs Services

INFRASTRUCTURE


  • UPS Redundancy
    N+1
  • UPS Description
    Two (2) 450 kVA UPS units with 12 minutes battery life
  • Generator Redundancy
    N+1
  • Generator Description
    Four (4) 400 kVA generators; enough fuel on-site for 24 hours at full capacity; eleven (11) diesel generators on-site
  • Cooling Redundancy
    N+1/2N
  • Cooling Description
    Multiple 20-ton Stulz CRAC units with both chilled water and DX cooling systems; average data center temperature at 21 degrees Celsius; hot aisle/cold aisle configuration with under-floor cooling

COMPLIANCE


  • --

    SSAE-16
  • --

    SSAE-18
  • --

    HIPAA
  • --

    PCI
  • --

    DIACAP
  • --

    Energy Star
  • --

    ISO
  • --

    FISMA
  • --

    FEDRAMP
  • --

    NIST
  • --

    SOC 1
  • --

    SOC 2
  • --

    SOC 3
  • --

    Uptime Institute MO Site Award
  • --

    Uptime Institute Tier III Constructed
  • --

    Uptime Institute Tier III Design

SERVICES


  • --

    Private Suites
  • --

    Dedicated Infrastructure
  • --

    Cloud
  • SLA 99.9%

SECURITY


  • --

    Perimeter Fencing
  • --

    Card Key Access
  • --

    CCTV
  • --

    Man Trap
Clear All

BACK TO PROFILE

REQUEST A QUOTE FROM beanfield Metroconnect FACILITY

Tell us a little about your needs before we connect you with a beanfield Metroconnect representative.

DATA CENTER REQUIREMENTS


BASIC INFORMATION


By clicking send, I agree that datacenterHawk will send this information to beanfield Metroconnect.

SEND QUOTE

GET A QUOTE