Data Realty

1440 Ignition Drive S

South Bend, IN

COLOCATION

About Data Realty Data Center

OVERVIEW


Data Realty operates this facility located at 1440 Ignition Drive S in South Bend. The building comes in at 48,000 in total SF and currently offers 2,400 kW of critical power. The UPS systems are 2N redundant and the generators are N+1 redundant.

POWER


??? NN

Commissioned Power

??? NN

Available Power

Login to view capacity data

??? NN

Under Construction Power

??? NN

Planned Power

  • Estimated Power Cost
    --
  • Single or Dual Feed
    Dual Feed
  • On-Site Substation
    No
  • Power Provider
    AEP
  • Number of Substations
    Two
  • Estimated kW/Cabinet
    2.00 - 16.00
  • Additional Information
    Some of the lowest power costs in the nation; facility has not experienced one power outage or interruption since opening; located on the former Studebaker corridor; one-foot concrete wall surrounding data suite; fully modular and self-supporting raised Bergvik Iso Flooring system

BUILDING


??? ??

Commissioned Space

??? ??

Available Space

Login to view capacity data

??? ??

Under Construction Space

??? ??

Planned Space

  • Status
    Operational
  • Building Size
    48000 SF
  • Year Built
    2012
  • Building Floors
    1
  • Building Owner
    Data Realty
  • Purpose Built or Retrofit
    Purpose Built
  • On-Site Office Space
    Yes
  • On-Site Conf Room
    Yes
  • On-Site Break Room
    Yes

GET A QUOTE

No Obligation. Free. Privacy Guaranteed.

Cabinet Requirements

Additional Options

Redundant power feed

Three-phase power


Committed Bandwidth*

Committed or "flat-rate" bandwidth is an unmetered connection where you can use any amount up to the limit for the same price every month.

Please enter the committed bandwidth amount

Burstable Bandwidth

Burstable or "fractional commit" is where you pay for a certain amount of bandwidth, but can utilize additional bandwidth as needed during times of peak demand. Additional charges will apply for utilizing bandwidth above the base level. E.g. "100 Mbps w/40Mbps Committed" or "20 Mbps burstable to 1000 Mbps"

{{ errors.first('burstableBandwidth') }}

Contact Information

CONNECTIVITY


Provider (3) PoPs Services
  • Cogent
    645 Fiber
  • Comcast
    375 Fiber
  • Intelligent Fiber Network
    10 Fiber

INFRASTRUCTURE


  • UPS Redundancy
    2N
  • UPS Description
    UPS via Mitsubishi Electrical 9900B Series; 500 kVA UPS with a very flat efficiency curve
  • Generator Redundancy
    N+1
  • Generator Description
    Multiple Caterpillar (CAT) 3512B generators with fuel tested and verified by a third party
  • Cooling Redundancy
    N+1
  • Cooling Description
    Eight (8) 50-ton computer room air handler (CRAH) units powered by dual electrical sources; water-based cooling system uses outside ambient air cooling

COMPLIANCE


  • --

    SSAE-16
  • --

    SSAE-18
  • --

    HIPAA
  • --

    PCI
  • --

    DIACAP
  • --

    Energy Star
  • --

    ISO
  • --

    FISMA
  • --

    FEDRAMP
  • --

    NIST
  • --

    SOC 1
  • --

    SOC 2
  • --

    SOC 3
  • --

    Uptime Institute MO Site Award
  • --

    Uptime Institute Tier III Constructed
  • --

    Uptime Institute Tier III Design

SERVICES


  • --

    Private Suites
  • --

    Dedicated Infrastructure
  • --

    Cloud
  • SLA 99.9%

SECURITY


  • --

    Perimeter Fencing
  • --

    Card Key Access
  • --

    CCTV
  • --

    Man Trap

NEARBY FACILITIES

We found 1 facilities near 1440 Ignition Drive S in South Bend, INDIANA.

Clear All

BACK TO PROFILE

REQUEST A QUOTE FROM Data Realty FACILITY

Tell us a little about your needs before we connect you with a Data Realty representative.

DATA CENTER REQUIREMENTS


BASIC INFORMATION


By clicking send, I agree that datacenterHawk will send this information to Data Realty.

SEND QUOTE

GET A QUOTE