DataBank

1100 Empire Central Place

Dallas, TX

DFW4

COLOCATION

About DFW4 Data Center

OVERVIEW


DataBank operates this data center in Dallas, located at 1100 Empire Central Place. This facility is purpose built and currently offers 3,000 kW of critical power to data center customers. Customers have a range of connectivity options at the facility to fiber providers like Time Warner Cable, AT&T and Level 3 (Lumen Technologies). Infrastructure in the data center includes N+1 UPS and 2N generator redundancies, with a cooling configuration of N+1.

4Q22 Dallas/Fort Worth Data Center Market Report

POWER


??? NN

Commissioned Power

??? NN

Available Power

Login to view capacity data

??? NN

Under Construction Power

??? NN

Planned Power

  • Estimated Power Cost
    --
  • Single or Dual Feed
    Dual Feed
  • On-Site Substation
    Yes
  • Power Provider
    --
  • Number of Substations
    Two
  • Estimated kW/Cabinet
    --
  • Additional Information
    --

BUILDING


??? ??

Commissioned Space

??? ??

Available Space

Login to view capacity data

??? ??

Under Construction Space

??? ??

Planned Space

  • Status
    Operational
  • Building Size
    98000 SF
  • Year Built
    --
  • Building Floors
    1
  • Building Owner
    DataBank
  • Purpose Built or Retrofit
    Purpose Built
  • On-Site Office Space
    Yes
  • On-Site Conf Room
    Yes
  • On-Site Break Room
    Yes

GET A QUOTE

No Obligation. Free. Privacy Guaranteed.

Cabinet Requirements

Additional Options

Redundant power feed

Three-phase power


Committed Bandwidth*

Committed or "flat-rate" bandwidth is an unmetered connection where you can use any amount up to the limit for the same price every month.

Please enter the committed bandwidth amount

Burstable Bandwidth

Burstable or "fractional commit" is where you pay for a certain amount of bandwidth, but can utilize additional bandwidth as needed during times of peak demand. Additional charges will apply for utilizing bandwidth above the base level. E.g. "100 Mbps w/40Mbps Committed" or "20 Mbps burstable to 1000 Mbps"

{{ errors.first('burstableBandwidth') }}

Contact Information

CONNECTIVITY


Provider (7) PoPs Services

INFRASTRUCTURE


  • UPS Redundancy
    N+1
  • UPS Description
    Brand new infrastructure with efficient UPS
  • Generator Redundancy
    2N
  • Generator Description
    Expandable to 8MW of generator capacity at 2N+1; four (4) generators
  • Cooling Redundancy
    N+1
  • Cooling Description
    Cold aisle containment; high-efficiency air cooled chillers with free cooling modules; multiple power paths for cooling equipment; 600 tons of cooling capacity

COMPLIANCE


  • --

    SSAE-16
  • --

    SSAE-18
  • --

    HIPAA
  • --

    PCI
  • --

    DIACAP
  • --

    Energy Star
  • --

    ISO
  • --

    FISMA
  • --

    FEDRAMP
  • --

    NIST
  • --

    SOC 1
  • --

    SOC 2
  • --

    SOC 3
  • --

    Uptime Institute MO Site Award
  • --

    Uptime Institute Tier III Constructed
  • --

    Uptime Institute Tier III Design

SERVICES


  • --

    Private Suites
  • --

    Dedicated Infrastructure
  • --

    Cloud
  • SLA 99.9%

SECURITY


  • --

    Perimeter Fencing
  • --

    Card Key Access
  • --

    CCTV
  • --

    Man Trap
Clear All

BACK TO PROFILE

REQUEST A QUOTE FROM DataBank DFW4 FACILITY

Tell us a little about your needs before we connect you with a DataBank representative.

DATA CENTER REQUIREMENTS


BASIC INFORMATION


By clicking send, I agree that datacenterHawk will send this information to DataBank.

SEND QUOTE

GET A QUOTE