About CL3 Data Center

OVERVIEW


CL3 is a facility operated by Equinix in the Calgary market. The facility boasts a total of 177,500 SF and offers customers access to office space, conference rooms and break rooms. Connectivity to Console Connect and Google Cloud is available for customer use. UPS systems are configured in N+1 redundancy with N+1/2N generators and N+1 cooling.

POWER


??? NN

Commissioned Power

??? NN

Available Power

Login to view capacity data

??? NN

Under Construction Power

??? NN

Planned Power

  • Estimated Power Cost
    $0.080 - 0.100
  • Single or Dual Feed
    Single Feed
  • On-Site Substation
    No
  • Power Provider
    Enmax
  • Number of Substations
    One
  • Estimated kW/Cabinet
    5.00 - 5.00
  • Additional Information
    --

BUILDING


??? ??

Commissioned Space

??? ??

Available Space

Login to view capacity data

??? ??

Under Construction Space

??? ??

Planned Space

  • Status
    Operational
  • Building Size
    177500 SF
  • Year Built
    1998
  • Building Floors
    1
  • Building Owner
    Equinix
  • Purpose Built or Retrofit
    Retrofit
  • On-Site Office Space
    Yes
  • On-Site Conf Room
    Yes
  • On-Site Break Room
    Yes

GET A QUOTE

No Obligation. Free. Privacy Guaranteed.

Cabinet Requirements

Additional Options

Redundant power feed

Three-phase power


Committed Bandwidth*

Committed or "flat-rate" bandwidth is an unmetered connection where you can use any amount up to the limit for the same price every month.

Please enter the committed bandwidth amount

Burstable Bandwidth

Burstable or "fractional commit" is where you pay for a certain amount of bandwidth, but can utilize additional bandwidth as needed during times of peak demand. Additional charges will apply for utilizing bandwidth above the base level. E.g. "100 Mbps w/40Mbps Committed" or "20 Mbps burstable to 1000 Mbps"

{{ errors.first('burstableBandwidth') }}

Contact Information

CONNECTIVITY


Provider (8) PoPs Services

INFRASTRUCTURE


  • UPS Redundancy
    N+1
  • UPS Description
    A/B/C UPS configuration
  • Generator Redundancy
    N+1/2N
  • Generator Description
    One local utility 25kV feed; C531 – 1.8MVA power capacity; C532 – 1.0MVA power capacity; C534 – 1.0MVA power capacity; C531 – three (3) 2 MW generators; C532, C532, C533, C534 – two (2) 2MW generators configured for 2N; branch circuit metering to cabinet viewable by the customer via CP; 24”x42” cabinets with 2x 208VAC/20A 3-phase PDUs
  • Cooling Redundancy
    N+1
  • Cooling Description
    C531 – 880 tons of cooling capacity using a closed loop glycol cooling system; C532 – 630 tons of cooling capacity using a direct expansion air cooled system; C533 & C534 – both 372 tons of cooling capacity using an indirect evaporative system

COMPLIANCE


  • --

    SSAE-16
  • --

    SSAE-18
  • --

    HIPAA
  • --

    PCI
  • --

    DIACAP
  • --

    Energy Star
  • --

    ISO
  • --

    FISMA
  • --

    FEDRAMP
  • --

    NIST
  • --

    SOC 1
  • --

    SOC 2
  • --

    SOC 3
  • --

    Uptime Institute MO Site Award
  • --

    Uptime Institute Tier III Constructed
  • --

    Uptime Institute Tier III Design

SERVICES


  • --

    Private Suites
  • --

    Dedicated Infrastructure
  • --

    Cloud
  • SLA 99.9%

SECURITY


  • --

    Perimeter Fencing
  • --

    Card Key Access
  • --

    CCTV
  • --

    Man Trap
Clear All

BACK TO PROFILE

REQUEST A QUOTE FROM Equinix CL3 FACILITY

Tell us a little about your needs before we connect you with a Equinix representative.

DATA CENTER REQUIREMENTS


BASIC INFORMATION


By clicking send, I agree that datacenterHawk will send this information to Equinix.

SEND QUOTE

GET A QUOTE