eStruxture

1080 Beaver Hall Suite 1512

Montreal, QC

MTL-5

COLOCATION

About MTL-5 Data Center

OVERVIEW


eStruxture's MTL-5 facility is located in Montreal. This facility is retrofit and currently offers 750 kW of critical power to data center customers. Cogeco Cable, Rogers Communications and beanfield Metroconnect are some of the fiber options available at MTL-5. On the infrastructure side, the data center offers N UPS redundancy and N+1 cooling.

1Q23 Montreal Data Center Market Report

POWER


??? NN

Commissioned Power

??? NN

Available Power

Login to view capacity data

??? NN

Under Construction Power

??? NN

Planned Power

  • Estimated Power Cost
    --
  • Single or Dual Feed
    Dual Feed
  • On-Site Substation
    No
  • Power Provider
    Hydro Quebec
  • Number of Substations
    --
  • Estimated kW/Cabinet
    3.00 - 5.00
  • Additional Information
    --

BUILDING


??? ??

Commissioned Space

??? ??

Available Space

Login to view capacity data

??? ??

Under Construction Space

??? ??

Planned Space

  • Status
    Operational
  • Building Size
    --
  • Year Built
    1967
  • Building Floors
    21
  • Building Owner
    --
  • Purpose Built or Retrofit
    Retrofit
  • On-Site Office Space
    No
  • On-Site Conf Room
    No
  • On-Site Break Room
    Yes

GET A QUOTE

No Obligation. Free. Privacy Guaranteed.

Cabinet Requirements

Additional Options

Redundant power feed

Three-phase power


Committed Bandwidth*

Committed or "flat-rate" bandwidth is an unmetered connection where you can use any amount up to the limit for the same price every month.

Please enter the committed bandwidth amount

Burstable Bandwidth

Burstable or "fractional commit" is where you pay for a certain amount of bandwidth, but can utilize additional bandwidth as needed during times of peak demand. Additional charges will apply for utilizing bandwidth above the base level. E.g. "100 Mbps w/40Mbps Committed" or "20 Mbps burstable to 1000 Mbps"

{{ errors.first('burstableBandwidth') }}

Contact Information

CONNECTIVITY


Provider (8) PoPs Services
  • Bell Canada
    56 Fiber
  • Cogeco Cable
    33 Fiber
  • Cogent Communications
    762 Fiber
  • Rogers Communications
    43 Fiber
  • TELUS Communications
    59 Fiber
  • Videotron
    14 Fiber
  • Zayo
    916 Fiber
  • beanfield Metroconnect
    19 Fiber

INFRASTRUCTURE


  • UPS Redundancy
    N
  • UPS Description
    Eaton Powerware UPS systems; Module 1 & 2: N redundancy; Module 3: N + 1 redundancy
  • Generator Redundancy
    N
  • Generator Description
    Diesel generator with 24 hours on-site fuel storage capacity
  • Cooling Redundancy
    N+1
  • Cooling Description
    DX based CRAC units; hot/cold containment available; cold aisle contained with polypropylene strip door; six (6) York packaged AC units mechanical system; redundant air distribution on all mechanical components

COMPLIANCE


  • --

    SSAE-16
  • --

    SSAE-18
  • --

    HIPAA
  • --

    PCI
  • --

    DIACAP
  • --

    Energy Star
  • --

    ISO
  • --

    FISMA
  • --

    FEDRAMP
  • --

    NIST
  • --

    SOC 1
  • --

    SOC 2
  • --

    SOC 3
  • --

    Uptime Institute MO Site Award
  • --

    Uptime Institute Tier III Constructed
  • --

    Uptime Institute Tier III Design

SERVICES


  • --

    Private Suites
  • --

    Dedicated Infrastructure
  • --

    Cloud
  • SLA 99.9%

SECURITY


  • --

    Perimeter Fencing
  • --

    Card Key Access
  • --

    CCTV
  • --

    Man Trap
Clear All

BACK TO PROFILE

REQUEST A QUOTE FROM eStruxture MTL-5 FACILITY

Tell us a little about your needs before we connect you with a eStruxture representative.

DATA CENTER REQUIREMENTS


BASIC INFORMATION


By clicking send, I agree that datacenterHawk will send this information to eStruxture.

SEND QUOTE

GET A QUOTE