Fogo Data Centers

340 Tom Reeve Drive

Carrollton, GA

COLOCATION

About Fogo Data Centers Data Center

OVERVIEW


This facility is operated by Fogo Data Centers and is located in the Atlanta data center market. The building comes in at 10,000 in total SF and currently offers 500 kW of critical power. The facility also offers N+1 generator redundancy and N+1 cooling redundancy.

1Q23 Atlanta Data Center Market Report

POWER


??? NN

Commissioned Power

??? NN

Available Power

Login to view capacity data

??? NN

Under Construction Power

??? NN

Planned Power

  • Estimated Power Cost
    --
  • Single or Dual Feed
    Dual Feed
  • On-Site Substation
    No
  • Power Provider
    --
  • Number of Substations
    Two
  • Estimated kW/Cabinet
    --
  • Additional Information
    --

BUILDING


??? ??

Commissioned Space

??? ??

Available Space

Login to view capacity data

??? ??

Under Construction Space

??? ??

Planned Space

  • Status
    Operational
  • Building Size
    10000 SF
  • Year Built
    --
  • Building Floors
    1
  • Building Owner
    Fogo Data Centers
  • Purpose Built or Retrofit
    --
  • On-Site Office Space
    Yes
  • On-Site Conf Room
    Yes
  • On-Site Break Room
    Yes

GET A QUOTE

No Obligation. Free. Privacy Guaranteed.

Cabinet Requirements

Additional Options

Redundant power feed

Three-phase power


Committed Bandwidth*

Committed or "flat-rate" bandwidth is an unmetered connection where you can use any amount up to the limit for the same price every month.

Please enter the committed bandwidth amount

Burstable Bandwidth

Burstable or "fractional commit" is where you pay for a certain amount of bandwidth, but can utilize additional bandwidth as needed during times of peak demand. Additional charges will apply for utilizing bandwidth above the base level. E.g. "100 Mbps w/40Mbps Committed" or "20 Mbps burstable to 1000 Mbps"

{{ errors.first('burstableBandwidth') }}

Contact Information

CONNECTIVITY


Provider PoPs Services
  • Data coming soon.

INFRASTRUCTURE


  • UPS Redundancy
    N+1
  • UPS Description
    400 kVA Flywheel UPS; 500 kVA Battery UPS
  • Generator Redundancy
    N+1
  • Generator Description
    Two (2) 1 MW diesel generators; 6,000 gallons on-site fuel; 72 run hours; multi-vendor refueling contracts
  • Cooling Redundancy
    N+1
  • Cooling Description
    Cold aisle containment; 200 tons of cooling; waterside economizing

COMPLIANCE


  • --

    SSAE-16
  • --

    SSAE-18
  • --

    HIPAA
  • --

    PCI
  • --

    DIACAP
  • --

    Energy Star
  • --

    ISO
  • --

    FISMA
  • --

    FEDRAMP
  • --

    NIST
  • --

    SOC 1
  • --

    SOC 2
  • --

    SOC 3
  • --

    Uptime Institute MO Site Award
  • --

    Uptime Institute Tier III Constructed
  • --

    Uptime Institute Tier III Design

SERVICES


  • --

    Private Suites
  • --

    Dedicated Infrastructure
  • --

    Cloud
  • SLA 99.9%

SECURITY


  • --

    Perimeter Fencing
  • --

    Card Key Access
  • --

    CCTV
  • --

    Man Trap
Clear All

BACK TO PROFILE

REQUEST A QUOTE FROM Fogo Data Centers FACILITY

Tell us a little about your needs before we connect you with a Fogo Data Centers representative.

DATA CENTER REQUIREMENTS


BASIC INFORMATION


By clicking send, I agree that datacenterHawk will send this information to Fogo Data Centers.

SEND QUOTE

GET A QUOTE