Global IP Networks

2020 Live Oak Street

Dallas, TX

COLOCATION

About Global IP Networks Data Center

OVERVIEW


Located in downtown Dallas on 1 ½ acres occupying the entire city square block 2020 Live Oak St. is a dedicated data center facility comprised of 147,000 square-feet. Built out to Tier III specifications the facility has 6 feeders available from the utility company’s switched network for the delivery of electricity. These feeders are used to feed an onsite secured vault containing numerous kVA transformers in an N+2 configuration. The switched network auto-failover capability coupled with the N+2 vault configuration makes a complete utility failure extremely unlikely. Designed for concurrent maintainability the facility has received an entire inspection and upgrade in 2014 -2015. This includes the installation of new ATS and primary utility service entrance switchgear. During the upgrade process all connections have been torqued to specification and all gear validated to meet industry standards. The facilities backup generator system are deployed to various areas of the facility configured as N+2 in a Channel A and Channel B failover configuration. All are connected to appropriately sized ATS (Automatic Transfer Switches), to feed UPS equipment and automatically and seamlessly switch electrical supply between S1 and S2 as necessitated.

1Q23 Dallas/Fort Worth Data Center Market Report

POWER


??? NN

Commissioned Power

??? NN

Available Power

Login to view capacity data

??? NN

Under Construction Power

??? NN

Planned Power

  • Estimated Power Cost
    $0.070 - 0.080
  • Single or Dual Feed
    Dual Feed
  • On-Site Substation
    No
  • Power Provider
    Oncor
  • Number of Substations
    More
  • Estimated kW/Cabinet
    1.00 - 9.00
  • Additional Information
    --

BUILDING


??? ??

Commissioned Space

??? ??

Available Space

Login to view capacity data

??? ??

Under Construction Space

??? ??

Planned Space

  • Status
    Operational
  • Building Size
    139182 SF
  • Year Built
    1938
  • Building Floors
    12
  • Building Owner
    Westdale Capital
  • Purpose Built or Retrofit
    Retrofit
  • On-Site Office Space
    No
  • On-Site Conf Room
    Yes
  • On-Site Break Room
    Yes

GET A QUOTE

No Obligation. Free. Privacy Guaranteed.

Cabinet Requirements

Additional Options

Redundant power feed

Three-phase power


Committed Bandwidth*

Committed or "flat-rate" bandwidth is an unmetered connection where you can use any amount up to the limit for the same price every month.

Please enter the committed bandwidth amount

Burstable Bandwidth

Burstable or "fractional commit" is where you pay for a certain amount of bandwidth, but can utilize additional bandwidth as needed during times of peak demand. Additional charges will apply for utilizing bandwidth above the base level. E.g. "100 Mbps w/40Mbps Committed" or "20 Mbps burstable to 1000 Mbps"

{{ errors.first('burstableBandwidth') }}

Contact Information

CONNECTIVITY


Provider (25) PoPs Services

INFRASTRUCTURE


  • UPS Redundancy
    2N
  • UPS Description
    UPS systems are configured in an “A”, “B” and “C” architecture so that any one unit on either channel can be offline for maintenance without impinging the operational environment.
  • Generator Redundancy
    N+2
  • Generator Description
    Except where a client requests a single feed only, the generator units are deployed to various areas of the facility configured as N+2 in a Channel A and Channel B failover configuration. All are connected to appropriately sized ATS (Automatic Transfer Switches), to feed UPS equipment and automatically and seamlessly switch electrical supply between S1 and S2 as necessitated.
  • Cooling Redundancy
    2N
  • Cooling Description
    All critical systems for CRAC and power control are fed from the same electrical infrastructure as are the critical client components. Additionally, all CRAC units are fed from alternating generators to insure the cooling load is maintained in any utility supply failure scenario.

COMPLIANCE


  • --

    SSAE-16
  • --

    SSAE-18
  • --

    HIPAA
  • --

    PCI
  • --

    DIACAP
  • --

    Energy Star
  • --

    ISO
  • --

    FISMA
  • --

    FEDRAMP
  • --

    NIST
  • --

    SOC 1
  • --

    SOC 2
  • --

    SOC 3
  • --

    Uptime Institute MO Site Award
  • --

    Uptime Institute Tier III Constructed
  • --

    Uptime Institute Tier III Design

SERVICES


  • --

    Private Suites
  • --

    Dedicated Infrastructure
  • --

    Cloud
  • SLA 99.9%

SECURITY


  • --

    Perimeter Fencing
  • --

    Card Key Access
  • --

    CCTV
  • --

    Man Trap
Clear All

BACK TO PROFILE

REQUEST A QUOTE FROM Global IP Networks FACILITY

Tell us a little about your needs before we connect you with a Global IP Networks representative.

DATA CENTER REQUIREMENTS


BASIC INFORMATION


By clicking send, I agree that datacenterHawk will send this information to Global IP Networks.

SEND QUOTE

GET A QUOTE