Duluth I is a colocation data center in Duluth operated by Involta. The building comes in at 40,000 in total SF and currently offers 300 kW of critical power. On the interconnectivity side, the facility offers connections to on-net fiber providers including Arvig Enterprises, Consolidated Communications and CenturyLink. Infrastructure in the data center includes 2N UPS and N generator redundancies, with a cooling configuration of N+1.

POWER


??? NN

Commissioned Power

??? NN

Available Power

Login to view capacity data

??? NN

Under Construction Power

??? NN

Planned Power

  • Estimated Power Cost
    --
  • Single or Dual Feed
    Dual Feed
  • On-Site Substation
    No
  • Power Provider
    --
  • Number of Substations
    --
  • Estimated kW/Cabinet
    --
  • Additional Information
    --

BUILDING


??? ??

Commissioned Space

??? ??

Available Space

Login to view capacity data

??? ??

Under Construction Space

??? ??

Planned Space

  • Status
    Operational
  • Building Size
    40000 SF
  • Year Built
    1978
  • Building Floors
    2
  • Building Owner
    Essentia Health System
  • Purpose Built or Retrofit
    Retrofit
  • On-Site Office Space
    No
  • On-Site Conf Room
    No
  • On-Site Break Room
    No

GET A QUOTE

No Obligation. Free. Privacy Guaranteed.

Cabinet Requirements

Additional Options

Redundant power feed

Three-phase power


Committed Bandwidth*

Committed or "flat-rate" bandwidth is an unmetered connection where you can use any amount up to the limit for the same price every month.

Please enter the committed bandwidth amount

Burstable Bandwidth

Burstable or "fractional commit" is where you pay for a certain amount of bandwidth, but can utilize additional bandwidth as needed during times of peak demand. Additional charges will apply for utilizing bandwidth above the base level. E.g. "100 Mbps w/40Mbps Committed" or "20 Mbps burstable to 1000 Mbps"

{{ errors.first('burstableBandwidth') }}

Contact Information

CONNECTIVITY


Provider (4) PoPs Services

INFRASTRUCTURE


  • UPS Redundancy
    2N
  • UPS Description
    Dual Path 120V/208V Starline Busway; UPS conditioned with battery backup
  • Generator Redundancy
    N
  • Generator Description
    Utility ~25% renewable (wind, solar, hydro), 800 kW diesel generator
  • Cooling Redundancy
    N+1
  • Cooling Description
    Adheres to ASHRAE environment guidelines, monitored - PacketPower; chillers with waterside economization; average of ~180 Days of economized cooling; overhead cooling - DataSox, hot aisle and cold aisle topology, cold aisle containment

COMPLIANCE


  • --

    SSAE-16
  • --

    SSAE-18
  • --

    HIPAA
  • --

    PCI
  • --

    DIACAP
  • --

    Energy Star
  • --

    ISO
  • --

    FISMA
  • --

    FEDRAMP
  • --

    NIST
  • --

    SOC 1
  • --

    SOC 2
  • --

    SOC 3
  • --

    Uptime Institute MO Site Award
  • --

    Uptime Institute Tier III Constructed
  • --

    Uptime Institute Tier III Design

SERVICES


  • --

    Private Suites
  • --

    Dedicated Infrastructure
  • --

    Cloud
  • SLA 99.9%

SECURITY


  • --

    Perimeter Fencing
  • --

    Card Key Access
  • --

    CCTV
  • --

    Man Trap

NEARBY FACILITIES

We found 1 facilities near 421 North Sixth Avenue E in Duluth, MINNESOTA.

Clear All

BACK TO PROFILE

REQUEST A QUOTE FROM Involta Duluth I FACILITY

Tell us a little about your needs before we connect you with a Involta representative.

DATA CENTER REQUIREMENTS


BASIC INFORMATION


By clicking send, I agree that datacenterHawk will send this information to Involta.

SEND QUOTE

GET A QUOTE