LightEdge

1435 Northridge Circle

Altoona, IA

COLOCATION

About LightEdge Data Center

OVERVIEW


Operated by LightEdge, this Altoona facility is located at 1435 Northridge Circle. The building comes in at 30,000 in total SF and currently offers 2,000 kW of critical power. Customers have a range of connectivity options at the facility to fiber providers like AT&T, Sprint and XO Communications. To ensure continuity of service, the facility maintains N+1 generator redundancy.

POWER


??? NN

Commissioned Power

??? NN

Available Power

Login to view capacity data

??? NN

Under Construction Power

??? NN

Planned Power

  • Estimated Power Cost
    --
  • Single or Dual Feed
    Dual Feed
  • On-Site Substation
    No
  • Power Provider
    --
  • Number of Substations
    Two
  • Estimated kW/Cabinet
    --
  • Additional Information
    --

BUILDING


??? ??

Commissioned Space

??? ??

Available Space

Login to view capacity data

??? ??

Under Construction Space

??? ??

Planned Space

  • Status
    Operational
  • Building Size
    30000 SF
  • Year Built
    2006
  • Building Floors
    1
  • Building Owner
    LightEdge
  • Purpose Built or Retrofit
    Purpose Built
  • On-Site Office Space
    Yes
  • On-Site Conf Room
    Yes
  • On-Site Break Room
    Yes

GET A QUOTE

No Obligation. Free. Privacy Guaranteed.

Cabinet Requirements

Additional Options

Redundant power feed

Three-phase power


Committed Bandwidth*

Committed or "flat-rate" bandwidth is an unmetered connection where you can use any amount up to the limit for the same price every month.

Please enter the committed bandwidth amount

Burstable Bandwidth

Burstable or "fractional commit" is where you pay for a certain amount of bandwidth, but can utilize additional bandwidth as needed during times of peak demand. Additional charges will apply for utilizing bandwidth above the base level. E.g. "100 Mbps w/40Mbps Committed" or "20 Mbps burstable to 1000 Mbps"

{{ errors.first('burstableBandwidth') }}

Contact Information

CONNECTIVITY


Provider (8) PoPs Services

INFRASTRUCTURE


  • UPS Redundancy
    N+1
  • Generator Redundancy
    N+1
  • Generator Description
    4.5 MW on-site diesel generators with 24 hrs diesel supply and 2 suppliers on contract
  • Cooling Redundancy
    N+1
  • Cooling Description
    240 tons of cooling capacity; all HVAC units are dual power fed and utilize variable speed fans; humidity set point of 44; HVACs support 1200 kW per DC

COMPLIANCE


  • --

    SSAE-16
  • --

    SSAE-18
  • --

    HIPAA
  • --

    PCI
  • --

    DIACAP
  • --

    Energy Star
  • --

    ISO
  • --

    FISMA
  • --

    FEDRAMP
  • --

    NIST
  • --

    SOC 1
  • --

    SOC 2
  • --

    SOC 3
  • --

    Uptime Institute MO Site Award
  • --

    Uptime Institute Tier III Constructed
  • --

    Uptime Institute Tier III Design

SERVICES


  • --

    Private Suites
  • --

    Dedicated Infrastructure
  • --

    Cloud
  • SLA 99.9%

SECURITY


  • --

    Perimeter Fencing
  • --

    Card Key Access
  • --

    CCTV
  • --

    Man Trap
Clear All

BACK TO PROFILE

REQUEST A QUOTE FROM LightEdge FACILITY

Tell us a little about your needs before we connect you with a LightEdge representative.

DATA CENTER REQUIREMENTS


BASIC INFORMATION


By clicking send, I agree that datacenterHawk will send this information to LightEdge.

SEND QUOTE

GET A QUOTE