South Reach Networks

36 NE 2nd Street, Suite 520

Miami, FL

COLOCATION

About South Reach Networks Data Center

OVERVIEW


This facility is operated by South Reach Networks and is located in the Miami data center market. The building comes in at 162,140 in total SF and currently offers 1,200 kW of critical power. On the interconnectivity side, the facility offers connections to on-net fiber providers including FiberLight, AT&T and Savvis. UPS systems are configured in N+1/2N redundancy with N+1/2N generators and N+1 cooling.

POWER


??? NN

Commissioned Power

??? NN

Available Power

Login to view capacity data

??? NN

Under Construction Power

??? NN

Planned Power

  • Estimated Power Cost
    --
  • Single or Dual Feed
    Dual Feed
  • On-Site Substation
    No
  • Power Provider
    Florida Power and Light
  • Number of Substations
    Two
  • Estimated kW/Cabinet
    1.20 - 6.20
  • Additional Information
    --

BUILDING


??? ??

Commissioned Space

??? ??

Available Space

Login to view capacity data

??? ??

Under Construction Space

??? ??

Planned Space

  • Status
    Operational
  • Building Size
    162140 SF
  • Year Built
    1925
  • Building Floors
    7
  • Building Owner
    Digital Realty
  • Purpose Built or Retrofit
    Retrofit
  • On-Site Office Space
    Yes
  • On-Site Conf Room
    Yes
  • On-Site Break Room
    No

GET A QUOTE

No Obligation. Free. Privacy Guaranteed.

Cabinet Requirements

Additional Options

Redundant power feed

Three-phase power


Committed Bandwidth*

Committed or "flat-rate" bandwidth is an unmetered connection where you can use any amount up to the limit for the same price every month.

Please enter the committed bandwidth amount

Burstable Bandwidth

Burstable or "fractional commit" is where you pay for a certain amount of bandwidth, but can utilize additional bandwidth as needed during times of peak demand. Additional charges will apply for utilizing bandwidth above the base level. E.g. "100 Mbps w/40Mbps Committed" or "20 Mbps burstable to 1000 Mbps"

{{ errors.first('burstableBandwidth') }}

Contact Information

CONNECTIVITY


Provider (16) PoPs Services

INFRASTRUCTURE


  • UPS Redundancy
    N+1/2N
  • UPS Description
    Four (4) UPS systems
  • Generator Redundancy
    N+1/2N
  • Generator Description
    Two (2) 500 kW diesel generators; automatic transfer connected to 72-hour+ fuel tanks; preferential fueling contracts
  • Cooling Redundancy
    N+1
  • Cooling Description
    Redundant glycol-based dry cooler systems with Liebert computer room air conditioning units offering minimum 120 sensible BTU per square-foot maintained at maximum 48 percent humidity

COMPLIANCE


  • --

    SSAE-16
  • --

    SSAE-18
  • --

    HIPAA
  • --

    PCI
  • --

    DIACAP
  • --

    Energy Star
  • --

    ISO
  • --

    FISMA
  • --

    FEDRAMP
  • --

    NIST
  • --

    SOC 1
  • --

    SOC 2
  • --

    SOC 3
  • --

    Uptime Institute MO Site Award
  • --

    Uptime Institute Tier III Constructed
  • --

    Uptime Institute Tier III Design

SERVICES


  • --

    Private Suites
  • --

    Dedicated Infrastructure
  • --

    Cloud
  • SLA 99.9%

SECURITY


  • --

    Perimeter Fencing
  • --

    Card Key Access
  • --

    CCTV
  • --

    Man Trap
Clear All

BACK TO PROFILE

REQUEST A QUOTE FROM South Reach Networks FACILITY

Tell us a little about your needs before we connect you with a South Reach Networks representative.

DATA CENTER REQUIREMENTS


BASIC INFORMATION


By clicking send, I agree that datacenterHawk will send this information to South Reach Networks.

SEND QUOTE

GET A QUOTE